Sun Fire X2100 M2 Hardware Specifications

Processor Options

ProcessorOne dual core Next-Generation AMD Opteron model 1200 Series (models 1220 (2.8 GHz), 1218 (2.6 GHz), 1210 (1.8 GHz))
MemoryUp to 8 GB; 4 DIMM slots, DDR2/667 Unbuffered ECC DIMMs (128 bit plus ECC databus), 512 MB, 1 GB, 2 GB DIMMs supported, installed in pairs
NetworkingFour Integrated 10/100/1000Base-T Ethernet ports
PCI Slots2x 8-lane PCI-Express

Mass Storage

Internal diskUp to two hot-pluggable 3.5" SATA II or SAS disk drives; 250 GB, 500 GB 7200 rpm SATA II or 146 GB 15K rpm SAS supported
Removable MediaUp to one EIDE DVD-ROM or DVD+/-RW DL drive
RAIDRAID 0/1/0+1 with optional 4-port SAS HBA; all supported operating systems with pair of SATA II or SAS drives
Option CardsSun has interoperability tested and supports a full suite of 4 GB and 2 GB Host Bus Adapters (HBAs). These HBAs offer unique features and benefits including Solaris integration and heterogeneous OS support. In the case of a Solaris environment, Sun HBAs combined with Sun Solaris OS provide the fastest, most reliable failover, highest availability, increased performance and dynamic load balancing by utilizing the Solaris SAN Foundation Suite drivers.

Software

Operating SystemsSolaris OS, Red Hat Enterprise Linux, SUSE Linux Enterprise Server, and Microsoft Windows. See supported Operating Systems.
LanguagesC/C++, FORTRAN (Solaris 10 OS), the Java programming language, all other standard Sun-supported languages
NetworkingONC, ONC+, NFS, WebNFS, TCP/IP, SunLink software, OSI, MHS, IPX/SPX, SMB technologies, XML
ManagementService processor with embedded Lights Out Management (LOM) standard.
Provides IPMI 2.0 in-band and out-of-band management.
Service processor is functionally equivalent to the ILOM used in the Sun Fire X4100 and X4200 servers.

Environmental

Operating temperature (single, non-rack system)5° C to 35° C (41°F to 95° F), 10% to 90% relative humidity, non-condensing, 27° C max wet bulb
Nonoperating temperature (single, non-rack system)-40 C to 65° C (-40° F to 149° F), up to 93% relative humidity, non-condensing, 38° C max wet bulb
Altitude (operating) (single, non-rack systemUp to 3,000 m, maximum ambient temperature is derated by 1° C per 300 m above 500 m
Altitude (nonoperating) (single, non-rack system)Up to 12000 m

Power

Quantity of Power SuppliesOne
Power Supply UL Maximum (AC input)6.5 Amps
Power Supply Rating (DC output)345 Watts

Dimensions and Weight

Height43 mm (1.7")
Width425.5mm (16.8")
Depth633.7 mm (25")
Weight (Maximum)10.7 kg (23.45 lbs)

Regulations

 Meets or exceeds the following requirements:
SafetyIEC 60950, UL/CSA60950, EN60950, CB scheme with all country differences
RFI/EMIFCC Class A, Part 15 47 CFR, EN55022, CISPR 22, EN300-386:v1.31, ICES-003
ImmunityEN55024, EN300-386:v1.3.2

Certifications

SafetyCE Mark, GOST, GS Mark, cULus Mark, CB scheme, CCC, S Mark
EMCCE Mark, Emissions and Immunity Class A Emissions Levels: FCC, C-Tick, MIC, CCC, GOST, BSMI, ESTI, DOC, S Mark
OtherLabeled per WEEE (Waste Electrical and Electronic Equipment) Directive, Reduction of Hazardous Substances Compliant