Sun Fire V490 Hardware Specifications

Processor Options

ProcessorCombine up to four 2.1 GHz UltraSPARC IV+ processors.
Combine up to four 1.8 GHz or 1.5 GHz UltraSPARC IV+ processors and/or 1.35 GHz UltraSPARC IV processors.
ArchitectureSuperscalar SPARC V9, ECC Protected
Processor modulesOne or two dual processor/memory modules
Cache per UltraSPARC IV+ processorLevel 1: 64-KB data and 64-KB instruction per pipeline
Level 2: 2 MB shared on-chip
Level 3: 32 MB shared external

Main Memory

Main MemoryA system maximum of 64 GB when configured with four processors

Standard Interfaces

NetworkTwo 10/100/1000 Mbps Ethernet
I/OFC-AL disk controller
SerialRJ45 serial port
Expansion capabilitySix PCI slots compliant with PCI specification Revision 2.1 (2 @ 66 MHz, 64 bits wide, 3.3 volts; 4 @ 33 MHz, 64 bits wide, 5 volts)
USBTwo (compliant with USB Revision 1.0)

Mass Storage

Host adaptersInternal IDE (supports DVD and/or DVD R/W drive)
Internal diskUp to 2 3.5" x 1.0" 15K-RPM FC-AL disks (146-GB capacity), providing a maximum total capacity of 292 GB
External diskSun StorageTek D240
Sun StorageTek S1
Sun StorageTek 3120
Sun StorageTek 3310 SCSI RAID/JBOD
Sun StorageTek 3320
Sun StorageTek 3510 FC RAID/JBOD
Sun StorageTek 3511
Sun StorageTek 6140 Array
Sun StorageTek 6920
Sun StorageTek 9910/9960/9970/9980
External tapeSun StorageTek DAT 72 desktop tape drive
Sun StorageTek LT0-2 desktop tape drive
Sun StorageTek LT0 2V desktop tape drive
Sun StorageTek LT0-3 desktop tape drive
Sun StorageTek SDLT 320 desktop tape drive
Sun StorageTek SDLT 600 desktop tape drive
Sun StorageTek C2
Sun StorageTek C4
Sun StorageTek SL500
Sun StorageTek SL700/SL1400 tape library
Sun StorageTek SL8500 tape library

Software

Operating systemThe minimum OS version for 1.5 GHz and 1.8 GHz and 2.1 GHz UltraSPARC IV+ processors is Solaris 9 9/05 or Solaris 10 3/05 HW1
(minimum version)The minimum OS version for 1.35 GHz UltraSPARC IV processors is Solaris 8 2/04, Solaris 9 4/04, or Solaris 10 3/05
Enterprise infrastructure softwareSun Java Enterprise System
Sun Management Center
Sun N1 System Manager

Power supplies

Power suppliesInput per power supply/system of 1600 watts (mfg. rating)
Maximum AC input1847 W per power supply
Maximum DC output1448 W per power supply

Environment

AC power200–240 VAC, 47–63 Hz, 2078 VA
Operating temperature5° C to 35° C (41° F to 95° F), 20% to 80% relative humidity, non condensing, 27° C max. wet bulb
Sun Fire V490 systems with 2.1 GHz processors: ASHRAE Class 3 (35C/900m), and/or 28C/10kft
Non operating temperature-20° C to 60° C (-4° F to 140° F), 95% relative humidity, non condensing

Regulations

RegulationsMeets or exceeds the following requirements:
SafetyUL/CSA-60950-1, EN60950-1, IEC60950-1 CB Scheme with all country deviations, IEC825-1, 2, CFR21 part 1040, CNS14336
ErgonomicsEK1–ITB–2000
RFI/EMCEN55022 Class A, 47 CFR 15B Class A, ICES Class A, VCCI Class A, AS/NZ 3548 Class A, CNS 13438 Class A, KSC 5858 Class A, GB 9254 Class A, EN61000-3-2, GB 17625.1, EN61000-3-3
ImmunityEN55024/CISPR24
TelecommunicationsEN300-386
X-ray (for monitors)DHHS 21 Subchapter J; PTB German X-ray Decree
Regulatory markingsCE, FCC, ICES-003, C-tick, VCCI, GOST-R, BSMI, MIC, UL/cUL, UL/S-mark
OtherRestriction of Hazardous Substances (RoHS) directive 2002/95/EC
Labeled per Waste Electrical and Electronic Equipment (WEEE) Directive

Dimensions and Weight

Height222 mm (8.75 in.)
Width446 mm (17.5 in.)
Depth610 mm (24.0 in.)
Weight35.8 kg (79 lb.) (minimum)
44 kg (97 lb.) (maximum)