Sun Fire V440 Hardware Specifications

Processor Options

NumberOne to four
ArchitectureUltraSPARC® IIIi (1.062, 1.28, or 1.593 GHz)
Cache memory64 KB data, 32 KB instruction and 1 MB integrated L2

Main Memory 

Capacities4 DIMM slots per processor
Registered DDR-1 SDRAM
System configurations from 2 GB to 32 GB

Standard Interfaces 

EthernetTwo 10/100/1000 BaseT Ethernet
One 10 BaseT Ethernet (network management)
PCISix internal PCI 2.2 compliant expansion slots:
Three 64 bit 33/66 MHz 3.3V full-length (slots 2, 4, 5)
Three 64 bit 33 MHz 5V full-length (slots 0, 1, 3)
SCSIOne Ultra320 SCSI (LVD)
System Configuration CardFront accessible for transfer of system configuration information, including host ID
SerialOne TIA/EIA-232-F asynchronous (DB9) Port
One TIA/EIA-232-F (RJ45) Port (management)
USBFour OHCI-1.1 Compliant Interfaces, supporting dual speeds of 12 and 1.5 Mbits/sec each

Internal Mass Storage

DisksUp to four hot plug Ultra320SCSI 36GB, 73GB, or 146GB Disks
DVD-ROMOne Slim-line ATAPI DVD-ROM

Environment

AC input90 - 264 V AC (47- 63 Hz)
Input power650 W (Max)
570 W (Typical)
Heat output2218 Btu/hr for operation @ 100 VAC to 240 VAC
TemperatureOperating: 5°C to 40°C (41°F to 104°)
Nonoperating: -40°C to 60°C (-40°F to 140°)
HumidityOperating: 20% to 80% relative humidity, noncondensing, 27°C max wet bulb
Nonoperating: Up to 93% relative humidity, noncondensing, 38°C max wet bulb
AltitudeOperating: Up to 3000m, maximum ambient temperature is derated by 1°C per 500m above 500m
Nonoperating: Up to 12000m
Acoustic noiseOperating: 6.7 Bels
Idling: 6.7 Bels
VibrationOperating: 0.0001 g2/Hz, 5 to 150 Hz, -12db/octave slope 150 to 500 Hz
Nonoperating: 0.001 g2/Hz, 5 to 150 Hz, -12db/octave slope 150 to 500 Hz
ShockOperating: 3.0 g peak, 11 milliseconds half-sine pulse —IEC 60068-2-27
Nonoperating: 15.0 g peak, 11 milliseconds half-sine pulse; 1.0 inch roll-off front to back, 0.5 inch roll-off side to side —IEC 60068-2-27
Handling Drops60 mm, 1 drop per corner, 4 corners—IEC 60068-2-31
Threshold Impact0.85m/s, 3 impacts per caster, all 4 casters, 25 mm step-up—ETE
1010-01
Number of cords2 (max)

Regulations

Meets or exceeds the following requirements
SafetyUL approval to UL 60950, EN60950, C22.2 No.60950, and CB Report for IEC 950; all including Amendments 1, 2, 3, 4 and 11 and full worldwide deviations. TUV approval to EN60950/IEC 950. GOST languages Certification for Eastern Block countries. Korean MIC Certification. China CCC mark using UL as agent. CE Declaration of Conformance (SMI self-declaration) to The Electromagnetic Compatibility Directive and Low Voltage Directive with accompanying "Technical Data File". Approval to Argentinian standards using UL as agent.
RFI/EMI47 CFR 15B (Code of Federal Regulations, Part 15, Subpart B) Class A; EN55022 Class A per EMC Directive 89/336/EEC (CE Mark); VCCI Class A; Industry Canada ICES-003; AS/NZ 3548 (Australia/New Zealand); CNS 13438 (Taiwan); KSC 5858 (MIC Mark/Korea)
ImmunityIEC 1000
EN55024 per EMC Directive 89/336/EEC, including
IEC 61000-4-2 Electrostatic discharge immunity test
IEC 61000-4-3 Radiated, radio-frequency, electromagnetic field immunity test
IEC 61000-4-4 Electrical fast transient/burst immunity test
IEC 61000-4-5 Surge immunity test
IEC 61000-4-6 Immunity to conducted disturbances, induced by radio frequency fields
IEC 61000-4-8 Power frequency magnetic field immunity test
IEC 61000-4-11 Voltage dips, short interruptions and voltage variations immunity tests
Line DistortionEN 61000-3-2 per EMC Directive 89/336/EEC
Voltage Fluctuations and FlickerEN 61000-3-3 per EMC Directive 89/336/EEC

Clearance and Service Access

Front36 in.(91.4 cm)
Rear36 in.(91.4 cm)

Dimensions and Weights

Height174 mm (6.85 in.)
Width440 mm (17.3 in.)
Depth635 mm (25 in.)
Weight37 kg (82 lb.) fully configured