Processor Options |
Processor |
Combine up to twenty-four 1.95 GHz processors and/or 1.8 GHz or 1.5 GHz UltraSPARC IV+ and/or 1.35 GHz UltraSPARC IV processors |
| Architecture |
Superscalar SPARC V9, ECC protected |
| Cache per UltraSPARC IV+ processor |
Level 1: 64 KB data and 64 KB instruction per pipeline |
| Level 2: 2 MB on-chip |
| Level 3: 32 MB external |
System |
Processor/memory boards |
Up to six Uniboard CPU/memory boards, with four processors each, and up to 64 GB per board; maximum 24 processors per system |
| Main Memory |
Up to 384 GB per domain |
| I/O |
32 PCI-X slots (twenty-four 100 Mhz and eight 33 MHz) |
| System interconnect |
9.6-GB/sec. Sun Fireplane interconnect. System bus with redundant data, address, and response crossbar interconnect |
| System bandwidth |
9.6-GB/sec. sustained bandwidth, 67.2-GB/sec. aggregate bandwidth |
| System controller |
Two per system |
| Boot device |
Sun StorageTek D240 Media Tray, Sun StorageTek S1 Array, and the Sun StorageTek 3210. Array may be used as boot, data-storage, data-load, data-interchange, and data backup devices |
Mass Storage |
External compatibility |
Direct attach to Sun StorageTek tape libraries and disk arrays, including: Sun StorageTek 3000, 6000, and 9000 families, providing excellent linear scalability |
Resource Management |
Standard |
Dynamic System Domains, |
| Solaris Resource Manager, |
| Solaris Bandwidth Manager |
Software |
Operating System (minimum version) |
The minimum OS version for 1.95 GHz, 1.5 GHz and 1.8 GHz UltraSPARC IV+ processors is Solaris 9 9/05 or Solaris 10 3/05 HW1 |
| The minimum OS version for UltraSPARC IV processors is Solaris 8 2/04, Solaris 9 4/04, or Solaris 10 3/05 |
| Enterprise software |
Sun Java Enterprise System |
| Languages |
C |
| C++ |
| Pascal |
| FORTRAN |
| Java |
| Networking |
ONC/NFS |
| TCP/IP |
| SunLink |
| OSI |
| X.25 |
| DCE |
| Netware |
| System Management and Enterprise Computing |
Sun Management Center |
| Sun Cluster |
| Sun HPC ClusterTools |
| System and network management |
Solaris Web Start, Solstice AdminSuite, Suite, Solstice Domain Manager, Solstice Enterprise Manager, Solstice DiskSuite, Solstice Backup, VERITAS File System, VERITAS Volume Manager, Sun Cluster, Sun HPC ClusterTools |
Environmental |
AC power |
200-240V single phase AC, 47-63 Hz, with two 11/13 Amp circuits redundant with another two on a separate grid |
| Power cords |
Four |
| Operating temperature |
5° C to 35° C (41° F to 95° F) 20% to 80% relative humidity, non condensing |
| Non operating temperature |
-20° C to 60° C (-4° F to 140° F) 5% to 93% relative humidity, non condensing |
| Altitude |
Up to 3,048 m (10,000 ft.) |
| Up to 2,134 m (7,000 ft.) for 1.8GHz and 1.95 GHz UltraSPARC IV+ |
Regulations |
Regulations |
Meets or exceeds the following requirements: |
| Safety |
UL 60950, third-edition USA CAN/CSA-C22.2 No. 60950-00, Canada EN 60950, third-edition, Europe S Mark, Argentina Gost-R, Russia CB Scheme with all national deviations |
| Emissions |
EN55022 Class A, Europe EN6100-3-2 / 3-3, Europe FCC Class A, USA ICES-003 Class A, Canada VCCI Class A, Japan CNS-13438, (BSMI-Taiwan) AS/NZ 3548 (C-tick), Australia Gost-R, Russia |
| Immunity |
All European requirements EN55024, EN61000-4-2, EN61000-4-3, EN61000-4-4, EN61000-4-5, EN61000-4-6, EN61000-4-8, EN61000-4-11, and EN300-386 |
| Regulatory markings |
CE, FCC, ICES-003, C-tick, VCCI, Gost-R, BSMI, UL/cUL/S Mark, TUV-GS, MIC, RoHS |
Dimensions and Weight |
Height |
190.5 cm (75.0 in.) |
| Width |
61.0 cm (24.0 in.) |
| Depth |
134.6 cm (53.0 in.) |
| Weight |
544.3 kg (1200.0 lb.) |
| Power cord |
4.6 m (15.0 ft.) |