Processor Options | Processor | Combine up to twelve 1.95 GHz UltraSPARC IV+ processors and/or 1.8 GHz UltraSPARC IV+ and/or 1.5 GHz UltraSPARC IV+ processors and/or 1.35 GHz UltraSPARC IV processors |
| Architecture | Superscalar SPARC V9, ECC protected |
| Cache per UltraSPARC IV+ processor | Level 1: 64 KB data and 64 KB instruction per pipeline |
| Level 2: 2 MB on-chip |
| Level 3: 32 MB external |
System | Processor/memory boards | Up to three CPU/memory boards*, with four processors each, and up to 64 GB per board; maximum 12 processors per server |
| *The Sun Fire E2900 server CPU/memory board is common, and therefore interchangeable, with the Sun Fire V1280 server. However, these boards are not identical to and thus not inter-changeable with the Sun Fire E4900–E25K server Uniboard technology. |
| Main Memory | Up to 192 GB per system |
| PCI-X | Six short PCI-X slots (64-bit 100 MHz,3.3V) |
| One integrated Ultra-320 SCSI (one internal and one external port) |
| Two Gigabit Ethernet ports with another two on a separate grid |
| System interconnect | 9.6-GB/sec. Sun Fireplane interconnect. System bus with redundant data, address and response crossbar interconnect |
| System bandwidth | 9.6-GB/sec. sustained bandwidth, 31.2-GB/sec. aggregate bandwidth |
Storage | Internal | Two 146-GB 15K rpm Ultra3-SCSI internal disks |
| DVD-ROM internal drive |
| Tape drive (optional) |
| External compatibility | Direct attach to Sun StorageTek tape libraries and disk arrays, including: Sun StorageTek 3000, 6000, and 9000 families, providing excellent linear scalability x |
Resource Management | Standard | Solaris Resource Manager, Solaris Bandwidth Manager |
Software | Operating System (minimum version) | The minimum OS version for 1.95 GHz, 1.5 GHz and 1.8 GHz UltraSPARC IV+ processors is Solaris 9 9/05 or Solaris 10 3/05 HW1 |
| The minimum OS version for UltraSPARC IV processors is Solaris 8 2/04, Solaris 9 4/04, or Solaris 10 3/05 |
| Enterprise software | Sun Java Enterprise System |
| Languages | C |
| C++ |
| Pascal |
| FORTRAN |
| Java |
| Networking | ONC/NFS |
| TCP/IP |
| SunLink |
| OSI |
| X.25 |
| DCE |
| Netware |
| System Management and Enterprise Computing | Sun Management Center |
| Sun Cluster |
| Sun HPC ClusterTools |
Environmental | AC power | 200-240V single phase AC, 47-63 Hz, with two 11/13 Amp circuits redundant with another two on a separate grid |
| Optimum | 22° C (72° F) at 45% non condensing humidity |
| Range | 5° C to 35° C (41° F to 95° F) at 10% to 80% non condensing humidity |
| Altitude | Up to 3,048 m (10,000 ft.) |
| Up to 2,134 m (7,000 ft.) for 1.8GHz and 1.95 GHz UltraSPARC IV+ |
Dimensions and Weight | Height | 52.7 cm (20.75 in.)12RU |
| Width | 44.5 cm (17.5 in.) |
| Depth | 55.8 cm (22.0 in.) excluding cable arm |
| Weight | 110-132 kg (240-290 lb.) |
| Rackmount enclosure | All Sun racks and most third-party 24-in. (600 mm) and deeper racks, two per 4-post rack, one per 2-post rack |
Regulations | Regulations | Meets or exceeds the following requirements: |
| Safety | UL 60950, third-edition USA CAN/CSA-C22.2 No. 60950-00, Canada EN 60950, third-edition, Europe S Mark, Argentina Gost-R, Russia CB Scheme with all national deviations |
| Emissions | EN55022 Class A, Europe EN6100-3-2 / 3-3, Europe FCC Class A, USA ICES-003 Class A, Canada VCCI Class A, Japan CNS-13438, (BSMI-Taiwan) AS/NZ 3548 (C-tick), Australia Gost-R, Russia |
| Immunity | All European requirements EN55024, EN61000-4-2, EN61000-4-3, EN61000-4-4, EN61000-4-5, EN61000- 4-6, EN61000-4-8, EN61000-4-11, and EN300-386 |
| Regulatory markings | CE, FCC, ICES-003, C-tick, VCCI, Gost-R, BSMI, UL/cUL/S Mark, TUV-GS, MIC, RoHS |
Key RAS Features | Key RAS Features | Dynamic Reconfiguration (DR) of processor/memory boards, hot CPU upgrades, redundant Sun Fireplane interconnect, redundant network connections, hot-swap disks, smart fans, 2N redundant hot-swap power supplies, Auto Diagnosis & Recovery, hardened operating system kernel, hardened I/O drivers, Systems Configuration Card, proactive self diagnostics, end-to-end data integrity including ECC, CPU off-lining, memory page retirement, after-kernel hot patching, and cluster support. |