Sun Fire 3800 Hardware Specifications

Processor Options

NumberTwo to 8
Architecture750 MHz, 900MHz, 1050MHz or 1200 MHz UltraSPARC[tm] Cu (copper based) III
Cache per processorPrimary (L1): 32 KB instruction, and 64 KB data cache
Secondary (L2): 8 MB, ECC protected
CPU interfacePacket-switch crossbar connecting up to 2 CPU/Memory boards, and up to 2 I/O assemblies
System InterconnectFireplane, 9.6 GB/sec (at 150 MHz)

System Boards

Number of boardsMaximum of 2 CPU/Memory boards and 2 I/O assemblies
CPU/Memory boardTwo CPU's with 16 GB (max) Memory or four CPU's with 32 GB (max) memory 
PCI I/O Assemblyn/a
CompactPCI I/O AssemblySix CompactPCI slots supporting 6-3U cPCI cards
2 at 66/33 MHz, 3.3V (slots 0 and 1)
4 at 33 MHz, 5V (slots 2 through 5)

Main Memory

32 GB memory (max) per 4 CPU's or 16 GB memory (max) per 2 CPU's on a CPU/Memory board
Maximum system memory capacity of 64 GB (2 × 32 GB)
1GB DIMMs are not supported on 750MHz CPU/Memory boards.
Note: The UltraSPARC III processor contains an integrated memory controller which is responsible for memory management of local memory and for running diagnostics on the CPU/Memory board. Therefore, memory capacity is directly related to the number of CPU's.

Standard Interfaces

System ControllerResponsible for the overall control of the system. Each System Controller includes one RS-232/423 (DB25) serial interface and one 10/100BASE-T ethernet/fast ethernet (RJ45) interface. Dual system controllers are standard on the Sun Fire 6800.

Internal Mass Storage

Sun StorEdge[tm] D240 Media TrayA 2U-high, rack-mounted unit into which two UltraWide SCSI3 disk drive, and one DVD drive and one DDS4 tape drive can be fitted. The DVD and DDS4 devices can be replaced by extra disk drives if required.

Power Supplies

The Sun Fire 3800-6800 server family can be configured with N"4" redundant DC bulk power supplies, which are hot swappable. The DC bulk power supplies provide power for all of the Sun Fire 3800-6800 systems' internal requirements, on a load-shared 48VDC power bus. The base package comes with 2 power supplies.

Environment

AC input100 VAC: 47 - 63 Hz, 24 A (max configuration)
120 VAC: 47 - 63 Hz, 19.7A (max configuration)
200 - 240 VAC: 47 - 63 Hz, 11.4 A (max configuration)
Input power100 VAC: 2280 W
120 VAC: 2240 W
200 - 240 VAC: 2170 W
Heat output100 VAC: 7775 BTU/hr
120 VAC: 7645 BTU/hr
200 - 240 VAC: 7385 BTU/hr
TemperatureOptimal: 21° C to 23° C (70° F to 73.5° F)
Operating: 5° C to 35° C (41° F to 95° F) - derate 2° C for every 1 km up to 3 km
Nonoperating: -20° C to 60° C (-4° F to 140° F)
HumidityOptimal: 45% to 50% relative humidity
Operating: 20% to 80% relative humidity, noncondensing (27° C max wet bulb)
Nonoperating: 5% to 93% relative humidity, noncondensing (38° C max wet bulb)
AltitudeOperating: 3000 m (10,000 ft.)
Nonoperating: 12,000 m (40,000 ft.)
Acoustic noiseOperating: 6.9 bels
VibrationOperating: 0.15 G, 5 - 500 Hz (swept sine)
Nonoperating: 0.6 G, 5 - 500 Hz (swept sine), vertical axis
0.3 G, 5 - 500 Hz (swept sine), horizontal axis
ShockOperating: 3 G peak, 11 milliseconds half-sine pulse
Number of cords13
1 One power cord for each power supply installed. Minimum required is two and maximum is three.

Regulations

Meets or exceeds the following requirements
SafetyUL 1950, CSA 950, TUB EN60950, CB Scheme (Worldwide Deviation)
RFI/EMIFCC Class A, ICES 003 Class A, DOC Class A, EN55022 Class A, VCCI Class A, BSMI Class A, EN61000-3-2 & EN61000-3-3
ImmunityEN55024, EN50082-1
HarmonicsEN61000-3-2

Dimensions and Weights

Height38.1 cm (15.0 in.)
85.7 cm (33.75 in.) shipping
Width45 cm (17.72 in.)
63 cm (24.75 in.) shipping
Depth88.4 cm (34.8 in.)
105.5 cm (41.5 in.) shipping
Weight104 kg (230 lb.) approximate
117.9 kg (260 lb.) approximate shipping
Power Cord2.5 m (8.2 ft.)