Processor Options |
Processor Specifications |
Up to 4 SPARC64 VI Dual core processors |
| SPARC V9 Architecture, ECC protected |
| Cache per SPARC64 Level 1: 128 KB D-cache and 128 KB I-cache |
| Level 2: 5 MB on-chip |
| Clock speed: 2.1GHz |
System |
System Specifications |
Up to 2 CPU boards (CMU), 2 CPUs per board |
| Main memory Up to 128 GB per domain / system, up to 4 memory boards with maximum 32GB per board using DDR2 4GB memory DIMMs |
| Up to 5 I/O slots with 4 PCIe slots each and 1 PCI-X on one I/O tray |
| Up to 25 PCIe or PCI-X slots with optional External I/O Expansion Unit |
| High-speed, low-latency interconnect system bus with redundant data, address, and response crossbar interconnect |
| System Bus bandwidth (Memory) 32GB/s PEAK, 12.7GB/s STREAM |
| System Bus bandwidth (IO) 8GB/s PEAK |
| 2 1Gb Ethernet ports |
| Service Processor for system management |
| Up to 2 dynamic domains |
Storage |
Storage Specifications |
Boot device: Up to 2 internal, 2.5" SAS boot disks |
| External direct, SAN or NAS attach to Sun StorageTek compatible tape libraries and disk arrays, including Sun StorageTek 3X00, 5X00, 6X00, and 9X00 families |
Resource Management |
Resource Management |
Dynamic Domains, Solaris Resource Manager including Solaris Containers |
Software |
Software Specifications |
Solaris 10 (11/06) |
| Languages |
C, C++, Pascal, FORTRAN, Java |
| Networking |
ONC/NFS, TCP/IP, SunLink Netware |
| System |
Sun Management Center monitoring, Solaris Web Start, Solstice Domain Manager, Solstice Enterprise Manager, Solstice Backup |
| Value Added Software |
Sun Cluster, Sun HPC ClusterTools, Sun Java Enterprise System |
Environmental |
Power |
AC power 100–240 VAC 1-phase (50/60 Hz), 12 amp per power cord, 1-2 power cords |
| Plug NEMA-L6-20P (U.S.) or IEC 309-IP44 (INTL) IEC 60320 C19 connector. |
| Receptacle type: IEC 60320 C20 |
| Operating temperature |
5°C to 35°C (41°F to 95°F), 20% to 80% relative humidity, noncondensing |
| Nonoperating temperature |
-20°C to 60°C (-4°F to 140°F) 8% to 80% relative humidity, noncondensing |
| Altitude |
Up to 3048 m (10,000 ft.) |
Regulations |
Safety |
CSA/UL-60950, EN60950, IEC950 CB Scheme with all national deviations |
| RFI/EMC |
EN55022/CISPR22 Class A, FCC CFR47 Part 15 Class A, EN61000-3-2, EN61000-3-3 |
| Immunity |
EN55024, EN61000-4-2, -4-3. -4-5. -4-6, -4-8 & -4/11 |
| Regulatory Markings |
CE, FCC, ICES, C-tick, VCCI, GOST-R, BSMI, MIC, CSA/UL |
| Other Marks |
WEEE and Chinese RoHS |
RAS |
Key RAS Features |
End-to-end ECC protection |
| Guaranteed data path integrity |
| Automatic recovery |
| Auto-reconfiguration after reboot |
| Blacklist of failed field replacement units (FRUs) |
| Blacklist of failed ASIC's |
| Reconfiguration and recovery of centerplane with an ASIC failure |
| Instruction retry |
| Processor SRAM and register protection |
| ECC and and extended protection for memory |
| Memory mirroring |
| Predictive self-healing |
| Full hardware redundancy |
| Fault-isolated Dynamic Domains |
| Dynamic Reconfiguration |
| Auto Diagnosis and Recovery |
| Proactive self-diagnostics |
| Hot-swap of memory processors power cooling and I/O |
| Online upgrades (add new resources while system is operational) |
| Concurrent maintenance (service while system is operational) |
| Redundant network connections |
| Redundant storage connections |
| Hardened operating system kernel |
| Live operating system upgrades |
| Journaled file system |
| Hardened I/O drivers |
| CPU off-lining |
| Memory page retirement |
| Cluster support |
Dimensions and Weight |
Height |
26.3 cm (10.34 in.) |
| Width |
44.4 cm (17.48 in.) |
| Depth |
81 cm (31.9 in.) |
| Weight |
84 kg (185 lb.) |