Supported Processors |
1.6-GHz Intel Itanium 2 processor |
Cache 6 MB |
| 1.5-GHz Itanium 2 processor |
Cache 4 MB |
Memory |
Memory slots |
64 (16 per cell board) |
| Minimum memory (Quad: 4 DIMMs) |
2 GB |
| Maximum memory capacity |
256 GB (64 GB per cell board) |
Internal Disks |
Maximum disk mechanisms |
4 |
| Maximum disk capacity |
1.2 TB |
| Internal Removable Media |
2 slots |
| DVD-ROM |
|
| DDS 4 DAT |
40 GB |
Core I/O |
Ultra3 SCSI-LVD |
Yes |
| 10/100/1000Base-T (RJ-45 connector) |
Yes |
| RS-232 serial ports (one console and one UPS) |
2 |
| 10/100Base-T port (Web and LAN console conn.) |
Yes |
I/O Buses and Slots |
Total Hot-plug PCI-X Slots (133 MHz×64 bits) |
16 |
| 14 Dual channel slots (1060 MB/s each) |
|
| 2 Single channel (530 MB/s each) |
|
Maximum I/O Cards |
Mass Storage |
8 |
| LAN |
2 |
| WAN |
16 |
| Multi-Function (Mass Storage / LAN) |
14 |
| Additional Interface Cards |
4 |
Electrical Characteristics |
AC Input power |
200-240V 50/60 Hz |
| Hot swap Power supplies |
6 total, 2 included with base |
| Redundant AC power inputs |
2 required, 4 cords for 2N |
| Typical maximum power dissipation for maximum processor, memory, disk, I/O configurations |
3800 VA (3724 W)
19A @200VAC |
| Marked Electrical for server |
5,400 VA (30A @180VAC) |
| Marked Electrical per line cord |
2700 VA (15A @180VAC) |
| Power factor at full load |
0.98 (approximately) |
| kW rating for UPS loading* |
6 |
Site Preparation |
Site planning and installation included |
Yes |
| Depth (in/mm) |
30 in (762 mm) |
| Width (in/mm) |
19 in (482 mm) |
| Height (in/mm/EIA) Racked |
29.75 in (755 mm)/17 units |
| Height (in/mm) Pedestal |
32.8 in (833 mm) |
| Weight (lbs/kg) |
171.4 kg (378 lbs) |
Environmental Characteristics |
Acoustics (sound power) at 25°C |
7.2 Bels LwA |
| Acoustics (sound power) at 30°C |
7.5 Bels LwA |
| Acoustics (operator/bystander) at 24°C |
61.0 dB LpA |
| Operating Temperature (up to 5000 ft)* |
41° to 95° F (5° to 35° C) |
| Non-operating Temperature |
-40° to 158° F (-40° to 70° C) |
| Maximum rate of temperature change |
68° F (20° C)/hour |
| Operating relative humidity |
15% to 80%, non-condensing, max. web bulb = 78.8° F (26° C) |
| Non-operating relative humidity |
5% to 90%, non-condensing |
| Operating altitude above sea level |
To 10,000 feet (3.0 km) |
| Non-operating altitude above sea level |
To 15,000 feet (4.5 km) |
Regulatory Compliance |
RMN |
RSVLA-0102 |
| Electromagnetic |
Complies with FCC Rules and Regulations, Part 15, as |
| Interference |
a Class A digital device. Manufacturer's Declaration to EN55022 Level A, VCCI Registered, Class 1, Korea RLL |
| Safety |
UL Listed, cUL Certified, compliant with EN 60950 |