Supported Processors |
1.3-GHz Intel® Itanium® 2 processor |
Cache 3 MB |
| 1.5-GHz Itanium 2 processor |
Cache 6 MB |
System Memory |
Minimum memory |
1 GB |
| Maximum memory capacity |
96 GB |
Internal Disks |
Max. disk mechanisms |
4 |
| Max. disk capacity |
438 GB |
Standard Integrated I/O |
Ultra160 SCSI-LVD |
Yes |
| 10/100/1000Base-T |
Yes |
| (RJ-45 connector) |
|
| RS-232 serial ports (multiplexed from DB-25 port) |
3 |
| 10/100Base-T management port (RJ-45 connector) |
Yes |
I/O buses and slots |
Total PCI X and PCI Slots |
10 |
| 3 133 MHz, 64 bit slots on 3 dedicated PCI X buses |
|
| 6 66 MHz, 64 bit slots distributed on 3 PCI X buses; 2 slots per bus |
|
| 1 33 MHz, 32 bit PCI slot; recommended for graphics card |
|
Maximum I/O Cards |
Mass Storage |
9-10 |
| LAN |
10 |
| WAN |
10 |
| Multi-Function (Mass Storage / LAN) |
10 |
| Additional Interface Cards |
2-10 |
Electrical Characteristics |
AC Input power |
100 240V 50/60 Hz |
| Hotswap Power supplies |
2 included, 3rd for N+1 |
| Redundant AC power inputs |
2 included, 3rd for N+1 |
| Typical current requirements at 230V |
5 A (shared across inputs) |
| Typical maximum power dissipation |
952 Watts |
| Theoretical maximum power dissipation |
2,089 Watts |
| Power factor at full load |
0.98 |
| Typical Heat dissipation (BTUs/hour) |
3250 |
| Maximum Heat dissipation (BTUs/hour) |
7135 |
Site Preparation |
Site planning and installation included |
No |
| Depth (in/mm) |
30.5 in (774 mm) |
| Width (in/mm) |
19 in (482 mm) |
| Rack Height (EIA/in/mm) |
7 U/12.25 in/322 mm |
| Pedestal Height (in/mm) |
14.5 in (368 mm) |
| Weight (lb/kg) Maximum |
160 lb (73 kg) |
Environmental Characteristics |
Acoustics (operator/bystander) |
<7.5 Bels LwA |
| at 77° F/25° C) |
|
| Operating Temperature |
41° to 95° F (5° to 35° C) |
| (up to 5000 ft/1524 m* |
|
| Non-operating Temperature |
-40° to 158° F (-40° to 70° C) |
| Maximum rate of temperature change |
50° F (10° C)/hour |
| Operating relative humidity |
15% to 80% RH non-condensing |
| Non-operating relative humidity |
5% to 90% non-condensing |
| Operating altitude above sea level |
1,0000 ft (3,000 m) maximum |
| Non-operating altitude above sea level |
1,5000 ft (4,600 m) maximum |
Regulatory Compliance |
Electromagnetic Interference |
Complies with FCC Rules and Regulations, Part 15 as a Class A digital device. Manufacturer's Declaration to EN55022 Level A, VCCI Registered, Class A, Korea RLL |
| Safety |
UL Listed, CSA Certified, TUV GS Mark compliant with EN 60950 and EN 41003 |