Supported Processors |
1.3-GHz Intel Itanium 2 processor |
Cache 3 MB |
| 1.5-GHz Intel Itanium 2 Processor |
Cache 6 MB |
HP mx2 Dual-processor Module
(Contains two 1.1 GHz Itanium 2 processors) |
Cache 4 MB |
| 1.5-GHz Intel Itanium 2 Processor |
Cache 4 MB |
| 1.6-GHz Intel Itanium 2 Processor |
Cache 6 MB |
System Memory |
Minimum memory |
1 GB |
| Maximum memory capacity |
128 GB |
Internal Disks |
Maximum disk mechanisms |
2 |
| Maximum disk capacity |
292 GB |
Standard Integrated I/O |
Ultra320 or Ultra160 SCSI-LVD |
2 channels |
10/100/1000Base-T
(RJ-45 connector) |
2 ports |
| RS-232 serial ports |
3 |
10/100Base-T management port
(RJ-45 connector) |
Yes |
| USB and VGA |
Yes |
I/O Buses and Slots |
Available PCI-X slots |
6 |
| Two 133 MHz, 64 bit slots on dedicated PCI X buses |
| Four 66 MHz, 64 bit slots distributed on 2 PCI X buses; 2 slots per bus |
Maximum I/O Cards (See supported I/O able for product specifics) |
Mass Storage |
3-6 |
| LAN |
6 |
| WAN |
6 |
Multi-Function
(Mass Storage / LAN) |
6 |
| Additional Interface Cards |
6 |
Electrical Characteristics |
AC Input power |
200-240V 50-60 Hz |
| Hot swap Power supplies |
1 included, 2nd for N+1 |
| Redundant AC power inputs |
1 included, 2nd for N+1 |
| Typical current requirements at 230V |
? A (shared across inputs) |
| Typical maximum power dissipation |
1065 Watts |
| Conservative maximum power dissipation |
1368 Watts |
| Power factor at full load |
0.95 or higher |
Typical Heat dissipation
(BTUs/hour) |
3600 |
| Maximum Heat dissipation (BTUs/hour) |
5500 |
Site Preparation |
Site planning and installation included |
No |
| Depth (in/mm) |
25.2 in/639 mm |
| Width (in/mm) |
17.32 in/440 mm |
Rack Height
(EIA/in/mm) |
6.9 in/4 U4/175 mm |
| Weight (lbs/kg) Maximum |
100 lb (45 kg) |
Environmental Characteristics |
Acoustics (operator/bystander) at 77° F (25° C) |
<7.2 Bels LwA |
Operating Temperature
(up to 5000 ft/1524 m) |
41° to 95° F (5° to 35° C) |
| Non-operating Temperature |
-40° to 158° F (-40° to 70° C) |
| Maximum rate of temperature change |
20° per hour |
| Operating relative humidity |
15% to 80% RH non-condensing |
| Non-operating relative humidity |
5% to 90% non-condensing |
| Operating altitude above sea level |
10000 ft (3000 m) maximum |
| Non-operating altitude above sea level |
15000 ft (4500 m) maximum |
Regulatory Compliance |
Electromagnetic interference |
Complies with FCC Rules and Regulations, Part 15 as a Class A digital device. |
| Manufacturer's Declaration to EN55022 Level A, VCCI Registered, Class A, Korea RLL |
| Safety |
UL Listed, CSA Certified, UL GS Mark compliant with EN 60950 and EN 41003 |