Processor board |
Processor cores: 1–4 |
| Processor modules: 1-2 |
| Chipset: HP zx2 |
| System bus bandwidth: 8.5 GB/s |
Dual-core processor modules |
Type: Dual-core Intel® Itanium® processor |
| 1.42 GHz/12 MB Dual-core (9120N) |
| 1.66 GHz/18 MB Dual-core (9140M) |
| Level 1 cache: 32 KB |
| Level 2 cache: 1 MB instruction/256 KB data |
| Level 3 cache: 12 MB (6 MB per core) and 18 MB (9 MB per core) |
Single-core processor modules |
Type: Intel® Itanium® processors 1.6 GHz/12 MB (9110N) |
| Level 1 cache: 32 KB |
| Level 2 cache: 1MB instruction/256 KB data |
| Level 3 cache: 12 MB |
Main memory |
Bus bandwidth: 12.8 GB/s |
| RAM type: Chip spare PC2-4200 ECC x4 single rank Registered DDR2 SDRAM |
| Capacity: 32 GB |
| Memory slots: 8 DIMM slots |
Operating systems |
HP-UX 11i v2 and v3 with HP Virtual Server Environment (choice of Mission-Critical, Enterprise, Technical Computing, or Foundation Operating Environment); |
| Microsoft® Windows® Server 2003, Enterprise and Datacenter Editions; |
| Red Hat Enterprise Linux 4 and 5 and Novell SUSE Linux Enterprise Server 10 |
| OpenVMS v8.3 (choice of Mission Critical, Enterprise, or Foundation Operating Environment) |
Internal storage devices |
Internal hard disk drive bays: 8-port Serial Attached SCSI (SAS) |
| Disk offerings: 36 GB (10 K rpm), 73 GB (10K rpm), 146 GB (10K rpm) Small Form |
| Factor Serial Attached SCSI (SAS) drives |
| Maximum storage: 1.2 TB |
| Removable media: 1 open bay for DVD-ROM or DVD+RW |
Expansion slots |
Choice of: |
| • All PCI-X Card Cage: 3 full-length PCI-X slots (2 @ 266 MHz/64-bit, 1 @ 133 MHz/64-bit) for 5.3 GB/s of I/O bandwidth (total bandwidth with core I/O is 7.0 GB/s) |
| • Combination Card Cage: 3 full-length slots (2 PCI Express slots @ 2.6 GB/s of bandwidth each, and 1 PCI-X slot @ 133 MHz/64-bit) for a total of 6.3 GB/s of I/O bandwidth (total bandwidth with core I/O is 8.0 GB/s) |
Core I/O and management processor interconnect |
Dual-port 10/100/1000Base-T Ethernet, 10/100Base-T LAN for Integrated Lights Out (iLO 2) management, dual-channel Serial Attached SCSI (SAS) |
Altitude |
Operating: 10,000 ft. (3 000 m) maximum |
| Non-operating: 15,000 ft. (4 600 m) maximum |
Temperature (Celsius and Fahrenheit) |
Operating: 41°F to 95°F (5°C to 35°C) |
| Non-operating: –40°F to +158°F (–40°C to +70°C) |
| Maximum rate of temperature change: 36°F (20°C) per hour |
Humidity |
Operating: 15% to 80% relative non-condensing |
| Non-operating: 8% to 85% non-condensing |
Physical dimensions (Rack form factor) |
Height: 3.4 in. (86 mm) 2U EIA |
| Width: 19.0 in. (482 mm) |
| Depth: 26.5 in. (672 mm) |
Physical dimensions (Pedestal form factor) |
Height: 20.2 in. (512 mm) |
| Width: 10.8 in. (275 mm) |
| Depth: 27.1 in. (688 mm) |
Net weight |
Maximum configuration (Rack form factor): 62 lb. (28 kg) |
| Maximum configuration (Pedestal form factor): 87 lb. (40 kg) |
Power requirements |
Maximum input current: 10A @ 100 Vms; 7A @ 200Vms |
| Line frequency: 50–60 Hz +/- 3 Hz |
| Maximum configuration: 798 W |
| Maximum configuration at idle: 567 W |
| Note: Power figures are per system, not per input line (power supply), and include losses in the power supplies. |
Power supply |
Maximum output: 800 W at 90 V to 132 V AC input/1000 W at 180 V to 264 V AC input |