Supported Processors |
1.3-GHz Intel® Itanium® 2 processor |
Cache 3 MB |
| 1.5-GHz Itanium 2 processor |
Cache 6 MB |
| 1.0-GHz Itanium 2 processor |
Cache 1.5 MB |
| 1.4-GHz Itanium 2 processor |
Cache 1.5 MB |
System Memory |
Minimum memory |
1 GB |
| Maximum memory capacity |
24 GB |
Internal Disks |
Maximum disk mechanisms |
3 |
| Maximum disk capacity |
900 GB |
Standard Integrated I/O |
Ultra320 SCSI–LVD |
2 channels |
| 10/100/1000Base-T (RJ-45 connector) |
1 port |
| 10/100Base-T (RJ-45 connector) |
1 port |
| RS-232 serial ports (general purpose) |
2 |
| 10/100Base-T management port (RJ-45 connector) |
Yes |
| VGA graphics |
Yes |
| USB |
4 |
I/O buses and slots |
Total PCI-X/PCI Slots |
4 |
| All four slots are 133-MHz, 64-bit slots on dedicated PCI-X buses |
|
Maximum I/O Cards |
Mass Storage |
39451 |
| LAN |
4 |
| WAN |
4 |
| Multi-Function (Mass Storage / LAN) |
39511 |
| Additional Interface Cards |
4 |
Electrical Characteristics |
AC Input power |
100-240V 50/60 Hz |
| Hot swap Power supplies |
1 included, 2nd for N+1 |
| Redundant AC power inputs |
1 included, 2nd for N+1 |
| Current requirements at 230V |
3.6 A (shared across inputs) |
| Typical maximum power dissipation |
600 Watts |
| Theoretical maximum power dissipation |
1,350 Watts |
| kW rating for UPS loading |
1.3 |
| Typical Heat dissipation (BTUs/hour) |
1945 |
| Maximum Heat dissipation (BTUs/hour) |
4375 |
Site Preparation |
Rack depth (in/mm) |
26.8 in (680 mm) |
| Rack width (in/mm) |
19 in (482 mm) |
| Rack height (EIA/in/mm) |
2U/ 3.4 in (86 mm) |
| Pedestal depth (in/mm) |
26.5 in (672 mm) |
| Pedestal width (in/mm) |
11.7 in (297 mm) |
| Pedestal height (in/mm) |
19.5 in (495 mm) |
| Weight (lb/kg) Maximum |
56 lb (25 kg) |
Environmental Characteristics |
Acoustics (operator/bystander) at |
<6.5 Bels LwA |
| 77° F (25° C) |
|
| Operating Temperature |
41° to 95° F (5° to 35° C) |
| (up to 5000 ft/1524 m)* |
|
| Non-operating Temperature |
-40° to 158° F (-40° to 70° C) |
| Maximum rate of temperature change |
50° F (10° C)/hour |
| Operating relative humidity |
15% to 80% RH non-condensing |
| Non-operating relative humidity |
8% to 85% non-condensing |
| Operating altitude above sea level |
10,000 ft (3,000 m) maximum |
| Non-operating altitude above sea level |
15,000 ft (4,572 m) maximum |
Regulatory Compliance |
Electromagnetic interference |
Complies with FCC Rules and Regulations, Part 15 as a Class A digital device. Manufacturer's Declaration to EN55022 Level A, VCCI Registered, Class A, Korea RLL |
| Safety |
UL Listed, CSA Certified, UL GS Mark compliant with EN 60950 and EN 41003 |