Supported Processors |
PA-8900 Dual core 1.1 GHz Processors |
L1 Cache (1.5-MB/core) 3 MB |
| L2 Cache 64 MB |
| PA-8900 Dual core 1.0 GHz Processors |
L1 Cache (1.5-MB/core) 3 MB |
| L2 Cache 64 MB |
| PA-8800 Dual core 1.0 GHz Processors |
L1 Cache (1.5-MB/core) 3 MB |
| L2 Cache 32 MB |
| PA-8800 Dual core 900 MHz Processors |
L1 Cache (1.5-MB/core) 3 MB |
| L2 Cache 32 MB |
Memory |
Memory slots |
32 (16 per cell board) |
| Minimum memory (Quad: 4 DIMMs) |
2 GB |
| Maximum memory capacity |
128 GB (64 GB per cell board) |
Internal Disks |
Maximum disk mechanisms |
4 |
| Maximum disk capacity |
1.2 TB |
| Internal removable media |
1 slot |
| DVD ROM |
|
| DDS 4 DAT |
40 GB |
Internal Removable Media |
1 slot |
DVD ROM |
| DDS 4 DAT (optional) 40-GB |
Core I/O |
Ultra3 SCSI-LVD |
Yes |
| 10/100/1000Base-T (RJ-45 connector) |
Yes |
| RS-232 serial ports (one console and one UPS) |
2 |
| 10/100Base-T port (Web and LAN console conn.) |
Yes |
I/O Buses and Slots |
Total Hot-plug PCI-X Slots (133 MHz×64 bits) |
15 |
| 14 Dual channel slots (1060 MB/s each) |
|
| 2 Single channel (530 MB/s each) |
|
Maximum I/O Cards |
Mass Storage |
8-15 |
| LAN |
15 |
| WAN |
15 |
| Multi-Function (Mass Storage / LAN) |
15 |
| Additional Interface Cards |
4-15 |
Electrical Characteristics |
AC Input power |
200-240V 50/60 Hz |
| Hotswap Power supplies |
2 total, included with base |
| Redundant AC power inputs |
2 required, 4 cords for 2N |
| Typical maximum power dissipation for maximum processor, memory, disk, I/O configurations |
2015 VA (1975 W) |
| Marked Electrical per server |
2640 VA (12A @ 220VAC) |
| Marked Electrical per line cord |
1320 VA (6A @ 220VAC) |
| Power factor at full load |
0.98 (approximately) |
| kW rating for UPS loading1 |
3 |
Site Preparation |
Depth (inches/mm) |
30 in (762 mm) |
| Width (inches/mm) |
19 in (482 mm) |
| Height (inches/mm/EIA) Racked |
17.5 in (445 mm) 10 units |
| Weight (lb/kg) |
101.6 kg./224 lbs. |
Environmental Characteristics |
Acoustics (sound power) at 25°C |
7.4 Bels LwA |
| Acoustics (sound power) at 30°C |
7.4 Bels LwA |
| Acoustics (operator/bystander) at 24°C |
58.4 dB LpA |
| Operating Temperature (up to 5000 ft)2 |
41° to 95° F (5° to 35° C) |
| Non-operating Temperature |
-40° to 158° F (-40° to 70° C) |
| Maximum rate of temperature change |
20°C/hour |
| Operating relative humidity |
15% to 80%, non-condensing, max. web bulb = 26°C |
| Non-operating relative humidity |
5% to 80%, non-condensing |
| Operating altitude above sea level |
To 3.0 km (10,000 feet) |
| Non-operating altitude above sea level |
To 4.5 km (15,000 feet) |
Regulatory Compliance |
RMN |
RSVLA-0102 |
| Electromagnetic Interference |
Complies with FCC Rules and Regulations, Part 15, as a Class A digital device. Manufacturer's Declaration to EN55022 Level A, VCCI Registered, Class 1, Korea RLL |
| Safety |
CSAus Certified, compliant with EN 60950 |