Supported Processors |
Two-Core 800 MHz PA 8900 Processor Module |
Cache Level 1 3MB (1.5 MB per core)
Cache Level 2 64MB (shared between cores) |
| Two-Core 1 GHz PA 8900 Processor Module |
Cache Level 1 3 MB(1.5 MB per core)
Cache Level 2 64MB (shared between cores) |
System Memory |
Minimum memory (HP-UX 11i v3 requires min 2 GB) |
1 GB |
| Maximum memory capacity |
128 GB |
Internal Disks |
Maximum disk mechanisms |
3 |
| Maximum disk capacity |
600 GB |
Standard Integrated I/O |
Dual port Ultra320 SCSI-LVD |
2 channel |
| 10/100/1000Base T (RJ 45 connector) |
2 port 3 |
| RS-232 serial ports |
3 |
| 10/100Base-T management port (RJ-45 connector) |
1 port |
| USB 2.0 |
Yes |
I/O Buses and Slots |
Available PCI X slots |
6 |
| 2 133 MHz, 64 bit slots on dedicated PCI X buses |
| 4 66 MHz, 64 bit slots distributed on 2 PCI X buses; 2 slots per bus |
Maximum I/O Cards |
Mass Storage |
1-6 |
| LAN |
6 |
| WAN |
6 |
| Multi-Function (Mass storage /LAN) |
6 |
| Additional Interface Cards |
1-6 |
Electrical Characteristics |
AC Input power |
200-240V 50-60 Hz |
| Hot swap power supplies |
1 included, 2nd for N+1 |
| Redundant AC power inputs |
1 included, 2nd for N+1 |
| Current requirements at 230V |
5.58 A (shared across inputs) |
| Typical maximum power dissipation |
1065 Watts |
| Conservative maximum power dissipation |
1368 Watts |
| Power factor at full load |
0.95 or higher |
| Typical heat dissipation (BTUs/hour) |
3600 |
| Maximum heat dissipation (BTUs/hour) |
5500 |
Site Preparation |
Rack depth (in/mm) |
25.2 in (639 mm) |
| Rack width (in/mm) |
17.32 in (440 mm) |
| Rack height (in/mm/EIA) |
6.87 in (174 mm/4 U) |
| Rack weight (lbs/kg) Max. |
96 lbs (43.55 kg) |
| Stand mounted depth (in/mm) |
27.36 in (95 mm) |
| Stand mounted width (in/mm) |
10.27 in (261 mm) |
| Stand mounted height (in/mm) |
20.9 in (530 mm) |
| Stand mounted weight (lbs/kg) |
111 lbs (504 kg) |
Environmental Characteristics |
Acoustics (operator/bystander) at 25°C |
<7.2 Bels LwA |
| Operating Temperature (up to 5000 ft) * |
+5 to +35 C |
| Non-operating Temperature |
-40 to +70 C |
| Maximum rate of temperature change |
10 C/hour |
| Operating relative humidity |
15% to 80% RH non cond. |
| Non-operating relative humidity |
5% to 90% non condensing |
| Operating altitude above sea level |
3000 m (10000 ft) max |
| Non-operating altitude above sea level |
4600 m (15000 ft) max |
Regulatory Compliance |
RMN |
RSVLA-0201 |
| Electromagnetic interference |
Complies with FCC Rules and Regulations, Part 15 as a Class A digital device. Manufacturer's Declaration to EN55022 Level A, VCCI Registered, Class A, Korea RLL |
| Safety |
UL Listed, CSA Certified, TUV GS Mark compliant with EN 60950 and EN 41003 |